Changing Gonad Buffer
Protocol for changing the ethanol out of gonad tissue vials.
We are switching to a 95Etoh-PureNoAdditives buffer. See types of ethanol page to understand why we are changing the ethanol out of gonad vials.
Steps for changing ethanol out of gonad tissue vials
- Centrigue the vial for 2 minutes at maximum speed
- Use a pipette, suck up the 95MGetoh ethanol buffer
Note: Make sure to not suck up any tissue!
- Add the 95Etoh-PureNoAdditives ethanol buffer
Exceptions
For cryovials that do not fit in the certifuge
Transfer the tissue into a labeled o-ring for long term storage
Then do the above steps!
For vials with too much gonad and not enough ethanol (over 1:5 tissue-to-ethanol)
You may remove some of the tissue from the vial, but make sure there is at least 1:5 tissue-to-ethanol.